Skip to main content

Table 1 Arterial blood gas and Polysomnography Parameters: Baseline vs. S-mode NIV vs. ST mode NIV

From: Spontaneous mode non-invasive ventilation fails to treat respiratory failure in a patient with Multi-mincore disease: a case report

  Baseline Spontaneous (S)
mode BiPAP
Spontaneous Timed
(ST) mode BiPAP
PaO2 45 57 80.6
PaCO2 83.4 73.5 55
PH 7.35 7.35 7.36
≥ 3% O2 desaturation/hr 149 57 20.7
Peak TcCO2 – total sleep time 88 88 68