Skip to main content

Table 1 Results of coagulation studies

From: Assessment of specific risks for the recurrence of deep vein thrombosis: a case report

Test

Result

Normal Range

Control

Prothrombin Time (PT)

19.7 s

10-12.8 s

11.4 s

Activated Partial Thromboplastin Time (APTT)

36.5 s

20-30 s

26.4 s

Thrombin Clottable Fibrinogen

2.5 g/L

2-4 g/L

 

Heat Precipitable Fibrinogen Measured by Lowry's Chemical Assay

2.5 g/L

2-4 g/L

 

Mixing studies with equal volume pooled normal plasma

Corrects PT and APTT

Variant Fibrinogen

Absent

  

Factor II activity

18%tblfn1

80-100%

 

Factor VII activity

9%tblfn1

80-100%

 

Factor X activity

18%tblfn1

80-100%

 

Antithrombin II heparin cofactor activity

100%

70-100%

 

Antithrombin III immunoreactive protein

100%

70-100%

 

Protein C activity (inactivation of FV & FVIII)

76%tblfn1

60-100%

 

Protein C immunoreactive levels

86%tblfn1

60-100%

 

Protein S immunoreactive free levels

62%tblfn1

60-100%

 
  1. 1Within expected range for degree of anticoagulation.